MIL-T-81785C(AS)
3.2.1.12 Interface.
The RFTS shall provide the following interfaces.
3.2.1.12.1 Liquid cooler interface. The RFTS shall interface with the
liquid cooler through coolant lines which enter the top of bay No. 1.
3.2.1.12.2 Clean air interface. The RFTS shall interface with the clean
air through ducts which enter the top rear of each console of the RFTS.
3.2-3.12.3 Electrical power interface. The RFTS shall interface with
electrical power for convenience outlets at one end of the convenience out-
let strip mounted at the top of the front of the RFTS. The RFTS shall inter-
face with the 400 Hz power form through power lines which enter the top of
bay no. 1. The RFTS shall interface with all other power forms through power
lines which enter the top of bay no. 4.
3.2.2 Utilities.
Applicable.
3.2.2.1 Electrical power. Applicable. Electrical power required for
operation of the RFTS shall be as listed in Table III. The 115/200 Volt (V),
400 Hertz (Hz), 3-phase leads entering the RFTS will be a separate bus not
shared with any other service from the facility source regulator.
TABLE III
RFTS ELECTRICAL POWER
3.2.2.2 Clean air. Applicable.
The RFTS requirements for clean air shall
not exceed 77 pounds per minute.
3.2.2.3
Potable water.
Not applicable.
Applicable,
3.2.2.4
Liquid coolant.
3.2.2.5
Helium.
Applicable.