of MIL-P-116.
Test Sets shall be packaged in accordance with the
5.1.2 Level C.
manufacturer's commercial practice.
5.2
Packing.
Test Sets packaged in accordance with 5.1.1 shall be packed
5.2.1 Level A.
in containers conforming to PPP-B-591 Fiberboard, Wood-Cleated, overseas
type, PPP-B-601, Wood, Cleated-Plywood, overseas type, PPP-B-621 Wood Nailed
and Lock-corner, Class 2, PPP-B-636 Fiberboard, Weather Resistant or PPP-B-40
Boxes shall be sealed, closed and
Fiberboard, Corrugated Triple-wall Class 2.
strapped for overseas shipment in accordance with the applicable box
Wood or cleated boxes shall be lined with
specification and appendix thereto.
a sealed waterproof case liner conforming to MIL-L-10547 except that when the
exterior container of Method IIb packages has strength and water resistance as
The gross weight
specified in PPP-B-636, a case liner will not be required.
of wood, wood-cleated or triple-wall corrugated boxes shall not exceed 200
pounds; fiberboard boxes shall not exceed the weight limitation of the
applicable box specification.
5.2.2 Level B.
Test Sets packaged in accordance with 5.1.1 shall be packed
in containers conforming to PPP-B-591 Fiberboard, Wood-Cleated, Domestic Type,
PPP-B-601, Wood-Cleated-Plywood, Domestic Type, PPP-B-621, Wood, Nailed and
Lockcorner, Class 1, PPP-B-636 Fiberboard Domestic or PPP-B-640 Fiberboard
Corrugated triple-wall, Class 1.
Boxes shall be sealed and closed in
The
accordance with the requirements of the applicable box specification.
gross weight of wood, wood-cleated or triple-wall corrugated boxes shall not
exceed 250 pounds; fiberboard boxes shall not exceed the weight limitations of
the applicable specification.
Test Sets shall be packed in containers in a manner to insure
5.2.3 Level C.
acceptance and sale delivery at destination.
Containers shall comply with the
consolidated freight classification rules or other regulations as applicable
to the mode of transportation.
5.3 Marking.
In addition to any special marking required by the contract or
order, marking for shipment shall be in accordance with MIL-STD-129.
The contractor shall comply with the requirements of
5.4 Cure Dates.
MIL-STD-480 as applicable.
6.
NOTES
6.1
Intended Use.
This Test Set is intended as a means of insuring that no
voltage is present on any pin on Connector 1316, ATM-7D/E Guidance and Control
Section prior to mating it with the warhead.
Procurement documents should specify the
6.2