MIL-T-51784C(AS)
Not applicable
3.2.1.8 Forced liquid cooling.
3.2.1.9 Space and weight limitations.
The maximum dimensions of the
IRTS shall be 24 inchcs by 14 inches by 14 inches. The maximum weight
shall be 50 pounds
3.2.1.10 Connectors.
Applicable
Not applicable.
3.2.1.11 Secondary electrical power.
5.2.1.12 Interface
The simulator shall interface with the Receiver,
Infrared R-1786( )/AWG-9.
Applicable.
3.2.2 Utilities.
3.2.2.1 Electrical power. Applicable. The IRTS shall require not more
than 300 volt-amperes of 115-volt, 400 Hertz (Hz), single-phase, Type I
power at a 0.9 power factor.
3.2.2.2
Not applicable
Clean air
3.2.2.3
Potable water-.
Not applicable.
3.2.2.4
Not applicable.
Liquid coolant.
3.2.2.5
Helium
Not applicable
3.2.2.6
Nitrogen.
Not applicable
3.2.2.7
Not applicable.
Hydraulic fluid,
3.2.3 Service conditions
5.2.3.1 Electrical
Applicable
3.2.3.2 Environmental.
Applicable.
3. 2.3.2.1 Organizational level. Applicable, except that the operating
The
intermittent opera-
temperature range shall be from -10 to
ting temperature extreme of MIL-T-21200 shall not apply.
3.2. 3.2.2 Intermediate level. Applicable, except that the operating
temperature range shall be from -10 to 55 C. The
intermittent opera-
ting temperature extreme of MIL-T-21200 shall not apply.
3.2.4 Maintainability.
Applicable.
Applicable.
3.2.4.1 Mean time to repair
3.2.4.2 Test points.
Applicable.
-3-
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business