MIL-T-81784C(AS)
3.6.6 Elapsed time meter, An elapsed time meter, conforming to MIL-M-
7793, shall be provided. The meter shall be readily visible during opera-
tion of the simulator and shall be capable of registering 9,999 hours.
3.6.7 Power cables. A detachable electrical power cable shall be pro-
vided in accordance with MIL-T-21200. The connector shall be MS3107A-16S-
8P with MS3057-8A cable clamp. The connector shall have 115 volt, 400 Hz,
single phase power on Pin A and return on Pin D. The length of the cable
shall be 30 + 1.0 feet.
3.6.8 Control cable. A detachable remote control cable with an irradi-
ance level selector switch shall be provided in accordance with MIL-T-21200.
The length of the cable shall be 30
1.0 feet.
4.
QUALITY ASSURANCE PROVISIONS
Applicable.
4.1 Responsibility for inspection.
Applicable.
4.2 General.
Applicable.
4.2.1 Classification.
Applicable.
4.2.3 In-process inspection.
Applicable.
4.2.4 In-process data,
4.2.5 Acceptance test plan.
Applicable.
Table I shall apply.
4.2.6 Test results.
Applicable.
4.2.7 Acceptance.
Applicable.
4.2,8 Utilities.
Applicable.
4.2.9 Configuration.
Applicable.
4.3 Tests.
4.3.1 Electrical and electronic items - operational run-in test.
Applicable.
4.3.2 Mechanical items.
Applicable.
4,4 Environmental test conditions.
Applicable.
4.5 Test location.
Applicable.
4.6 Acceptance schedule.
Applicable.
-6-