MIL-T-81784C(AS)
3.2.4.3 Shop replaceable assemblies (SRAs). Applicable.
3.2.4.4 Self test capability. Not applicable.
3.2.5 Reliability.
The mean-time-between-failures (MTBF) shall be 500
hours minimum.
3,2.5.1
Operating life.
Applicable.
3.2.5.2 Storage life.
Applicable.
3.2.5.3
Operational stability.
Applicable.
3.2.6 Electromagnetic interference (EMI).
Applicable except as follows:
a. MIL-STD-461, Tests CE01 and CE02 shall not apply.
b. MIL-STD-461, Tests CE03 and CE04 and the limits therein shall
apply except that transients occurring during functional non-
measurement periods may exceed the limits by 40 db as measured
at the simulator connector interface.
c. MIL-STD-461, Tests RS01, RS02, and RS04 shall not apply.
3.2.7 Utilitles protection.
Applicable.
3.2.7.1 Liquid cooling protection.
Not applicable,
3.2.7.2 Clean air protection,
Not applicable.
3.2.7.3 Electrical power protection.
Applicable.
3.2.8 Calibration cycle.
Applicable.
3.3 Performance.
3.3.1 General, The simulator shall provide three calibrated irradiance
simulated infrared (IR) targets to the infrared cryogenic refrigerator
receiver. The simulated IR targets shall be selectable by the remote con-
trol specified in 3.6.8,
3.3.2
Organizational level functional requirements.
Applicable,
3.3.3 Intermediate level functional requirements. Applicable when used
with the Low Frequency Test Station, OJ-215( )/AWM-23(V).
3.3.4
Warmup time.
Applicable.
-4-