MIL-I-81987(AS)
Temperature
Room ambient (30° 10°C)
Altitude
Normal ground
Vibration
None
Room ambient
Humidity
Input Power
108
to
118V
AC,
400Hz
20Hz
Voltage
3.5
Transportability - Transportability requirements shall be in
accordance with MIL-T-2200.
Characteristics -The performance of the equipment
3.6
Performance
shall be as specified herein.
3.7
Detail Requirements
3.7.1
Test Set, Indicator Monitor - The test set shall meet the following
requirements.
3.7.1.1
Function - The Indicator Monitor shall operate with the SM511IA/ASW
to provide the capability of fully testing An/ASW-27B or equivalent Data Link terminals at
the organizational level of maintenance. The indicator Monitor shall provide (1) the
capability of transmitting preprogrammed (stored) control messages via the SM511A/ASW,
(2) the capability of monitoring transmitted control or reply messages by displaying them
on a 42 bit binary readout, and (3) the capability to display specific reply messages on
appropriate numeric/discrete readouts.
Form Factor - The test shall be packaged in a combination case
3.7.1.2
that shall meet the requirements of MIL-T-21200. The case shall have dimensions of
20.62 inches wide by 14.50 inches deep by 11.00 inches high excluding protrusions.
The overall dimensions including protruding hardware shall be contained in an envelope
22.3 inches wide by 15.8 inches deep by 12.2 inches high.
3.7.1.3
Weight - The weight of the test set shall not exceed 53 pounds.
-6-